ROTHENBERGER ROTEST GW Digital V2.3 USB User Manual

Page 15

Advertising
background image

ENGLISH

15

Contents

of

Case

C A

1.......Manual bellows
2.......Water shut-off valve (black)
3.......Gas shut-off valve (red)
4.......Transmission cable (USB)
5.......1/8“ adapter
6.......1/2“ adapter
7.......T-adapter for water pipes
8.......Cross adapter for gas pipes
9.......Connecting tube
10.....RoData CD ROM
11.....Pressure sensor cable
12.....Low-pressure sensor (250 mbar) (blue ring)
13.....High-pressure sensor (20 bar) (red ring)
14.....Power supply unit
15.....ROTEST GW DIGITAL basic unit
16.....Hose adapter for burner test
17.....Leak quantity pump
18.....Pressure pump
19.....Precision pressure regulator

Key

Functions

Start or end action
Confirm selection
Calibration of zero point

Denial of requests
Continue in menu

Entry of PIN number. Entry of standard

pressures and standard test data


Pressure check

P1: Pressure at start of test
P2: Instantaneous pressure
Δ

P: Pressure differential

Temperature check

T1: Temperature at start of test
T2: Instantaneous temperature
Δ

T: Temperature differential

Time check

Δ

t: Time differential between instantaneous

time and beginning of test or start phase

STANDARD: Test duration as per national specifi

cations

During the start and test phase, the

instantaneous values of pressure and
temperature and the time can be called up by
pressing a key (

and

keys ).

Basic

Settings

Possible settings:
Language ......... Language 1, language 2

Pressure............ bar, Pascal, psi
Temperature .... °C, °F
To do this, when the unit is switched off, press the

and

keys at the same time for 3 seconds.

Switching On and Off

Switching on: Press the

key, enter the PIN no.

(see last page) and confirm with

.

Switching off: Press the

key for 5 seconds.

Automatic switch-off after 5 minutes without key
actuation (exception: start and test phases)
Change the battery if the “Battery empty” display
appears, or connect the power supply unit

Menu

Structure

After switching on, the main menu item

GAS PIPE is displayed.
To skip to the next main menu item:

To skip to the next submenu item:

At the end of the menu chain, the user is returned
to the main menu item GAS PIPE

GAS PIPE

LOAD TEST
LEAK TEST
USABILITY TEST
PRESSURE TEST

WATER PIPE

AIR MEDIUM
WATER MEDIUM

WASTEWATER EN1610

AIR MEDIUM
WATER MEDIUM

UNIT PRESSURE

LOW-PRESSURE SENSOR
HIGH-PRESSURE SENSOR

PRESSURE RECORDER

HIGH-PRESSURE SENSOR
LOW-PRESSURE SENSOR

DATA TRANSMISSION

SEND TO PC
RECEIVE FROM PC

MEMORY CLEAR

CLEAR O.K.?

MEMORY SPACE

AVAILABLE MEMORY