ROTHENBERGER ROWELD D 2/10 User Manual

Page 32

Advertising
background image

30

ENGLISH

7

Trouble-shooting

The following table lists potential operating upsets of the hand extruder, possible causes and
their remedies (fault diagnosis chart).
Should malfunctions occur which are not covered here or which cannot be traced back to the
cause stated, please contact ROTHENBERGER Werkzeuge GmbH.

Malfunction

Fault No.

Drive motor does not start

4, 5, 9, 10, 11, 12, 14, 15, 16, 17, 18, 19, 21

Drive motor switches off

5, 8, 9, 10, 11, 12, 14, 15, 16, 17, 18, 19, 21

No welding rod feed

1, 16, 17, 20

No extrudate conveyed out of welding shoe

1, 16

Extrudate output decreases during operation

1, 14, 16

No air supply

13

Integrated air supply system without function

22, 5

No hot air

2, 3, 4, 5, 18, 22

Hot air temperature below setpoint tempera-
ture

2, 3, 4, 8, 10, 14, 18, 22

Melt temperature below setpoint temperature

2, 3, 9, 11, 14

Extruder does not heat up

2, 3, 12, 22

Temperature above preset range

2, 3, 18, 19

Control fluctuates

3, 13, 19

Controller fault signal: OEAIR

2, 10, 19

Controller fault signal: OVERLD

22

Controller fault signal: OVHT

23

Controller fault signal: E

9

Controller fault signal: Fan-ERROR

19, 10

Controller signal: off

5, 6, 7, 8, 21