ROTHENBERGER ROWELD D 2/10 User Manual
Page 33
ENGLISH
31
Fault No. Possible causes
Remedy
1
Smaller or too small a welding rod
diameter
Use a larger welding rod diameter, if
necessary
2
Temperature sensor defective
1)
3
Temperature controller defective
1)
4
Cable connections defective
Check cable connections.
1)
5
Hot air temperature below start inter-
lock temperature
Allow hand extruder to heat up
6
Melt temperature below start interlock
temperature
Allow hand extruder to heat up
7
Preheat time for hot air too short
Allow hand extruder to heat up
8
Preheat time for melt too short
Allow hand extruder to heat up
9
Heating tape defective
1)
10
Air supply not constant
In the case of integrated air supply
system:
1)
11
Wrong rated voltage
Rated voltage > permissible voltage
Check mains voltage
Rated voltage < permissible voltage
Check mains voltage
1)
12
Extension cable heats up
Unroll cable reel, Check cable cross-
section (see also section “Safety”)
13
Extruder nozzle plugged with foreign
matter
Clean extruder
Extruder nozzle – left-hand thread
14
Drive unit defective
1)
15
Electronic control defective
1)
16
Controller programming error
1)
17
Welding rod feed
Remove welding rod
Observe instructions in section “Main-
tenance”!
Observe instructions for hand extruder
operation!
18
Carbon brushes of drive unit worn out
Replace carbon brushes
1)
19
Hot air supply system defective
1)
20
No mains voltage
Check voltage supply
21
Heating circuit not activated
22
Drive operates at overload
Heat up hand extruder, melt tempera-
ture too low
23
Temperature set on electronic control-
ler too high
Allow unit to cool down
1)
Rückfragen bei ROTHENBERGER Werkzeuge GmbH