ROTHENBERGER ROWELD D 2/10 User Manual

Page 33

Advertising
background image

ENGLISH

31

Fault No. Possible causes

Remedy

1

Smaller or too small a welding rod
diameter

Use a larger welding rod diameter, if
necessary

2

Temperature sensor defective

1)

3

Temperature controller defective

1)

4

Cable connections defective

Check cable connections.

1)

5

Hot air temperature below start inter-
lock temperature

Allow hand extruder to heat up

6

Melt temperature below start interlock
temperature

Allow hand extruder to heat up

7

Preheat time for hot air too short

Allow hand extruder to heat up

8

Preheat time for melt too short

Allow hand extruder to heat up

9

Heating tape defective

1)

10

Air supply not constant

In the case of integrated air supply
system:

1)

11

Wrong rated voltage

Rated voltage > permissible voltage
Check mains voltage
Rated voltage < permissible voltage
Check mains voltage

1)

12

Extension cable heats up

Unroll cable reel, Check cable cross-
section (see also section “Safety”)

13

Extruder nozzle plugged with foreign
matter

Clean extruder

Extruder nozzle – left-hand thread

14

Drive unit defective

1)

15

Electronic control defective

1)

16

Controller programming error

1)

17

Welding rod feed

Remove welding rod

Observe instructions in section “Main-
tenance”!
Observe instructions for hand extruder
operation!

18

Carbon brushes of drive unit worn out

Replace carbon brushes

1)

19

Hot air supply system defective

1)

20

No mains voltage

Check voltage supply

21

Heating circuit not activated

22

Drive operates at overload

Heat up hand extruder, melt tempera-
ture too low

23

Temperature set on electronic control-
ler too high

Allow unit to cool down

1)

Rückfragen bei ROTHENBERGER Werkzeuge GmbH

Advertising