Steamer display cabinet sdc-500, Maintenance (continued) – A.J. Antunes & Co SDC-500 9100532 User Manual

Page 10

Advertising
background image

SteaMer DiSplay Cabinet SDC-500

10

P/N 1010968 Rev. D 03/12

A.J. Antunes & Co.

display Codes

this section describes the different display codes and their meanings.

TEMP

UP

TEMP

DOWN

TEMP

SCALE

F

C

O

O

TEMP

UP

TEMP

DOWN

TEMP

SCALE

F

C

O

O

During the initial warm-up period, the unit will display the

following sequence of codes:

1. “8888” for one second.

2. “cH-1” for one second.

3. the unit’s setpoint temperature for one second.

4. “cH-1” for one second.

5. the unit’s setpoint temperature.

6. the unit’s actual cabinet temperature.

Press the

temp up button and the unit will display the

setpoint temperature. this figure shows an example setpoint

temperature of 155°f displayed on the console.

note: press and hold the temp sCale button for 2–3

seconds to toggle between displaying the temperature in

fahrenheit and Celsius.

“Hi” flashes if the actual cabinet temperature exceeds 250°f

(121°c).

nOte: the thermistor should be 100k ohm +/- 2% at room

temperature.

“OPeN” flashes if the thermistor is open or disconnected.

the unit will not call for heat.

nOte: the thermistor should be 100k ohms +/- 2% at

room temperature.

“PO” flashes when the input voltage to the unit is below 100

Vac or above 135 Vac. if this occurs, you should contact

your authorized service agency to correct the problem.

nOte: If voltage is within normal ranges, then contact

your authorized service agency.

nOte: to reset a unit in this state, the supply voltage

must be within acceptable limits and the unit must be

turned off for five seconds before turning it back on.

maIntenanCe (continued)