Steamer display cabinet sdc-500, Operation, A.j. antunes & co – A.J. Antunes & Co SDC-500 9100532 User Manual

Page 8: Operating instructions, Hi-limit reset button, Setpoint temperature

Advertising
background image

SteaMer DiSplay Cabinet SDC-500

8

P/N 1010968 Rev. D 03/12

A.J. Antunes & Co.

Operating Instructions

1. Open the front Door.

2. Remove the Diffuser and shelves only if pouring water

directly into the unit instead of the Water tube.

3. Pour 7 quarts (5.6 liters) of clean tap water into the

Water Pan (figure 6).

nOte: the front water tube is also used to indicate the

unit water level. water should always be visible in the

tube and should not exceed the “maX” line (figure 3)

OperatIOn

Hi-limit reset button

a hi-limit thermostat turns off power to the unit if it overheats.

this may happen if the unit runs out of water. to reset this

thermostat:

1. turn the unit off. allow it to cool for 10 to 15 minutes.

2. check the water level. add water if needed.

3. Press the reset button located on the front of the unit

(figure 7).

4. Restart the unit.

If the unit requires continuous resetting, contact your

authorized service agency.

warnInG

Keep face away from cover and opening when remov-

ing product. steam can escape and cause injury.

CautIOn

do nOt pour water hotter than 120°f (48°C) into a cold

unit. resulting steam may cause injury.

4. Reinstall the Diffuser and shelves. then load product

into the unit and close the front Door.

5. turn the unit on. During the initial warm-up period, the

unit will display the following sequence of codes:

a. “8888” for one second.

b. “cH-1” for one second.

c. the unit’s setpoint temperature for one second.

d. “cH-1” for one second.

e. the unit’s setpoint temperature.

f. the unit’s actual cabinet temperature.

6. to remove product from the unit, open the front Door

and use tongs or a similar utensil to lift the product out.

nOte: Keep the front door closed unless adding or

removing product.

setpoint temperature

Your sDc-500 is factory programmed to operate at a specific

temperature called the setpoint temperature. to change the

setpoint temperature:

1. Press and hold the ▲ and ▼ buttons until the display

flashes.

2. Release the buttons.

3. Press ▲ or ▼ to raise or lower the Setpoint

temperature.

4. Release the buttons. the unit saves the new setpoint

temperature into memory.

nOte the sdC-500 has an adjustable temperature range

of 150°f–180°f (66°C–82°C).

nOte: to change the display between fahrenheit and

Celsius, press and hold the temp scale button for 2–3

seconds and release.

figure 6. filling sdC-500 with water

LIN

E

PO

WER

LIN

E

Funnel

(Not Included)

water can be poured

into the unit from the

front door or using the

water tube as shown

LINE

FULL

PUSH TO RESET

LINE

REFILL

LINE

figure 7. Hi-limit reset button

Advertising