EVOLUTION STEAMER OWNERS MANUAL

Page 14

CLEANING - CONNECTED MODELS

Warning: Do not use a water jet or pressure washer to clean the steamer

DAILY CLEANING
1) Turn the steamer off and wait for the steamer to cool.
2) Open the drain valve and allow the cooking compartment to drain completely. Remove

the pan racks, steam collector, overfill sensor and condensate tray for cleaning. Wipe

the inside of the cooking chamber, water sensors, pan rails, steam collector, overfill

sensor, and condensate tray with a clean cloth.

3) Re-install the overfill sensor, steam collector, pan rails and condensate tray. Leave the

door open overnight.

(NOTE: The steamer will not operate without the overfill sensor.)

WEEKLY CLEANING

1) Close the drain valve and add 1 cup (8 ounces or 0.24 liters) of white vinegar to the

cooking compartment. Start the steamer in the Cook Mode. The cooking compartment
will automatically fill with water. After 15 minutes, turn the steamer off and allow the
steamer to cool. Then open the drain valve and allow the water in the cooking chamber
to drain completely.

2) To rinse close the drain valve and start the steamer in the Cook Mode. The cooking

compartment will automatically fill with water. After 15 minutes turn the steamer off and
allow it to cool. Open the drain valve and let it drain completely.

3) Remove the pan rails, steam distributor, steam collector, overfill sensor and condensate

tray for cleaning. Clean the water sensors with a non-metallic cleaning pad.

4) Wipe the inside of the cooking chamber, water sensors, pan rails (Fig. 15), steam

distributor (Fig. 15), steam collector (Fig. 15), overfill sensor (Fig. 15), and condensate
tray with a clean cloth.

5) Install the overfill sensor and the steam collector , resting the steam distributor on top of

the steam collector align the 4 retaining fasteners and hand tighten, then install the pan
rails and the condensate tray. Leave the door open overnight.

6)

(NOTE: The steamer will not operate without the overfill sensor)

Steam Distributor

Fig. 15

Over-Fill Sensor

Connected Model Only

Steam Generator

Pan Rail

Steam Distributor