Installation, Waterline connection - connected models – AccuTemp EVOLUTION ELECTRIC STEAMER User Manual

Page 8

Advertising
background image

MP4008-0910

EVOLUTION STEAMER OWNERS MANUAL

Page 6

Check local codes to determine exactly what type of anti-backflow/anti-siphon device

is necessary to meet local requirements.

Design the water supply line so the unit can be moved for service. Install a manual

water shutoff valve between the water supply line and the steamer supply line.

The Garden Hose Thread (GHT) connector used must be NSF rated for food grade

service.

Do not apply pipe thread sealant to GHT connections.

Install a manual water shut-off valve (Main Water Shutoff Valve) (not provided)

between the cold water supply line and the appliance.

must be less than 180 °F.

A NSF rated reinforced rubber or braided stainless steel appliance hose rated for the

temperature and pressure of the water supply with a 3/4” garden hose type

connection is required.

The hose must not be sharply bent, kinked or twisted.

If the steamer is close to a wall, use a right angle fitting to prevent kinking the hose

Flush the water supply line before connecting the line to the appliance.

Connect the water supply line to the steamer.

DRAIN LINE CONNECTION –CONNECTED MODELS ONLY
Floor Drain

The steamer should be located close to but not over a floor drain. Connect a ¾” reinforced

rubber hose rated for 212° F or higher to the drain fitting underneath the steamer with a hose

clamp. Run the hose to the drain. DO NOT directly plumb the steamer to the drain, Leave a

one-inch air gap between the hose and the drain as shown in Fig 4.

WATERLINE CONNECTION - CONNECTED MODELS

Fig. 4

INSTALLATION

Advertising