EVOLUTION STEAMER OWNERS MANUAL

Page 15

WEEKLY CLEANING

1) Close the drain valve and add 1 cup (8 ounces or 0.24 liters) of white vinegar to the

cooking chamber and fill with approximately 2½ gallons of tap water , shut the door and

turn the steamer on.

2) After 15 minutes, turn the steamer off and allow the steamer to cool. Open the drain

valve and allow the cooking chamber to drain completely.

3) To rinse close the drain valve, fill with approximately 2½ gallons tap water , close the

door and start the steamer Cook Mode. Let it run for 15 minutes, turn the steamer off

and allow the steamer to cool. Open the drain valve and allow the cooking chamber to

drain completely.

4) Remove the pan racks, steam collector and steam distributor for cleaning. Clean the

water sensors with a non-metallic cleaning pad. Wipe the inside of the cooking chamber,

water sensors, pan rails (Fig. 16),steam distributor (Fig. 16), steam collector (Fig. 16).

5)

Install the steam collector first, resting the steam distributor on top of the collector align

the 4 retaining fasteners and hand tighten and then install the pan rails. Leave door

open overnight.

DAILY CLEANING

1) Turn the steamer off and wait for the steamer to cool.
2) Open the drain valve and allow the cooking chamber to drain completely. Remove

the pan rails (Fig. 16) and steam collector. Wipe the inside of the cooking chamber,

water sensors, pan rails and steam collector with a clean cloth.

3)

Install the steam collector and pan rails. Once the water in the drain pan has

sufficiently cooled empty the drain pan wipe down and replace . Leave the door

open overnight.

CLEANING - CONNECTIONLESS

Fig. 16

Steam Generator

Steam Distributor

Pan Rail

OPERATION