HID VertX EVO V1000 Wiring Examples Installation Guide User Manual

V1000 - access controller, V100 - door/reader interface card in / free out, V200 - input monitor interface

Advertising
background image

THIS DOCUMENT CONTAINS
PROPRIETARY INFORMATION.
IT MAY NOT BE DISCLOSED
TO OTHERS OR USED FOR
MANUFACTURING PURPOSES
WITHOUT PERMISSION FROM
HID CORPORATION.

FINISH

MATERIAL

EXCEPT AS NOTED

DIMENSIONS ARE IN INCHES

PER ANSI Y14.5M

.XX
+/-

.XXX
+/-

ANGLES
+/-

DO NOT SCALE DRAWING

APPROVALS

DATE

DWN

DSGN

CHK

APVD

APVD

FIND

NO

CAGE

NO

QTY

REQD

PART OR

IDENTIFYING NO

NOMENCLATURE OR

DESCRIPTION

IRVINE, CALIFORNIA

DWG TITLE

SIZE

CAGE CODE

DWG NO

REV

SCALE:

SHEET: 1 of

B

71000-902

A.1

1

N/A

VertX INSTALL WIRING

DIAGRAM EXAMPLE

.01

.005

1

READER PWR
GROUND
DATA0/DATA
DATA1/CLOCK
DATA RETURN
GREEN LED
RED LED
BEEPER
HOLD/CD PRESS
SHIELD

READER PWR

GROUND

DATA0/DATA

DATA1/CLOCK

DATA RETURN

GREEN LED

RED LED

BEEPER

HOLD/CD PRES

SHIELD

P7

READER 1

READER 2

P1

P4

V100-0

+ (IN1)
- (IN1)
+ (IN2)
- (IN2)

(IN3) +
(IN3) -
(IN4) +
(IN4) -

P2

P5

NO
C
NC
NO
C
NC

NO

C

NC

NO

C

NC

P3

P6

P8

P9

TERM
RES

RS-485
LOOP IN

RS-485
LOOP OUT

12VDC
IN

A B

SHIELD

A B

SHIELD

- +

+ -
TAMPER

+ -
AC
FAIL

+ -
BAT
FAIL

- +
12VDC
IN

0

READER PWR

GROUND

DATA0/DATA

DATA1/CLOCK

DATA RETURN

GREEN LED

RED LED

BEEPER

HOLD/CD PRES

SHIELD

(IN3) +
(IN3) -
(IN4) +
(IN4) -

READER PWR
GROUND
DATA0/DATA
DATA1/CLOCK
DATA RETURN
GREEN LED
RED LED
BEEPER
HOLD/CD PRESS
SHIELD

+ (IN1)
- (IN1)
+ (IN2)
- (IN2)

NO
C
NC
NO
C
NC

READER 1

+ -
TAMPER

READER 2

NO

C

NC

NO

C

NC

P3

P2

P1

P8

P9

P6

P5

P4

TERM
RES

RS-485
LOOP IN

RS-485
LOOP OUT

12VDC
IN

A B

SHIELD

A B

SHIELD

- +

1

V100-1

P7

+ -
AC
FAIL

+ -
BAT
FAIL

- +
12VDC
IN

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

POWER

RESET

COMM

TX - GREEN
RX - RED

DOOR
MONITOR

REX

STRIKE RELAY
(OUT 1)

AUX RELAY
(OUT 2)

DOOR
MONITOR

REX

STRIKE RELAY
(OUT 3)

AUX RELAY
(OUT 4)

0

2

3

4

5

6

7

8

9

10

11

12

13

14

15

DOOR
MONITOR

REX

DOOR
MONITOR

REX

STRIKE RELAY
(OUT 1)

STRIKE RELAY
(OUT 3)

AUX RELAY
(OUT 4)

AUX RELAY
(OUT 2)

POWER

RESET

COMM

TX - GREEN
RX - RED

TO 12 VDC
POWER SUPPLY

TO 12 VDC POWER SUPPLY

IN OUT

IN OUT

IN OUT

+
-

NO
C
NC

P3

P7

P4

V1000

P14

P11

A
B

SHIELD

NC
NC

A
B

SHIELD

NC
NC

+

-

NO

C

NC

P17

P18

P6

P5

P10

P13

P8

9

RS232

1

PORT1
TERM

RES

PORT2

TERM

RES

BATT

J1

PORT3
TERM

RES

PORT4
TERM
RES

IN OUT IN OUT OFF ON

TCP/IP

IN OUT IN OUT

A
B
SHIELD
NC
NC
A
B
SHIELD
NC
NC

ETHERNET

POWER

RESET

COMM

GREEN - COMM OK
RED - COMM FAIL

RS-485
PORT 1

RS-485
PORT 2

RS-485
PORT 4

RS-485
PORT 3

AUX INPUT 1

AUX INPUT 2

RELAY 2

RELAY 1

WHITE/BLUE

BLUE

GND

+
INPUT 1
-
+
INPUT 2
-
+
INPUT 3
-
+
INPUT 4
-
+
INPUT 5
-

+
INPUT 9
-
+
INPUT 10
-
+
INPUT 11
-
+
INPUT 12
-
+
INPUT 13
-

+
INPUT 6
-
+
INPUT 7
-
+
INPUT 8
-

+
INPUT 14
-
+
INPUT 15
-
+
INPUT 16
-

P1

P4

V200-2

P2

P5

P3

P6

NOT USED
NO
C
NC

RELAY 1

P8

P9

NOT USED

NO

C

NC

RELAY 2

TERM
RES

RS-485
LOOP IN

RS-485
LOOP OUT

12VDC
IN

IN OUT

A B SHIELD A B SHIELD - +

+ -
TAMPER

+ -
AC
FAIL

+ -
BAT
FAIL

- +
12VDC
IN

2

P7

POWER

RESET

COMM

TX - GREEN
RX - RED

0 1

3

4

5

6

7

8

9

10

11

12

13

14

15

WHITE/BLUE

BLUE

GND

TO 12 VDC POWER SUPPLY

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

A

A

B

B

C

C

D

D

R

S

-4

8

5

RS-485

R

S

-4

8

5

+ -

12 OR 24

VDC POWER

SUPPLY

- +

12 OR 24

VDC POWER

SUPPLY

- +

HORN OR

STROBE

12 OR 24

VDC POWER

SUPPLY

+ -

- +

12 OR 24

VDC POWER

SUPPLY

HORN OR

STROBE

- +

- +

12 OR 24

VDC POWER

SUPPLY

+ -

12 OR 24

VDC POWER

SUPPLY

HORN OR

STROBE

+ -

REX SWITCH

IN CRASH BAR

DOOR MONITOR

SWITCH N/C

STANDARD

MAG LOCK

CRASH

BAR

MAG LOCK

SWITCH

-
+
+
-

DOOR #1

- +

- +

DOOR MONITOR

SWITCH N/C

+ -

ELECTRIC DOOR

STRIKE (LOCK)

DOOR #2

-
+

READER

READER

SHIELD

YELLOW

WHITE

BLACK

ORANGE

RED

BROWN

GREEN

BLUE

RED

BLACK

GREEN

WHITE

ORANGE

BROWN

YELLOW

BLUE

SHIELD

W

H

IT

E

/B

L

U

E

B

L

U

E

G

N

D

PIR OR

REX

+
-

PIR'S

12 OR 24

VDC POWER

SUPPLY

- +

+ -

HORN OR

STROBE

GLASS BREAK

(SONIC)

GLASS BREAK

(SONIC)

SEE NOTE 4

TO 12 VDC

POWER SUPPLY

REX SWITCH

IN CRASH BAR

- +

-
+
+
-

ELEC LOCK

SWITCH

DOOR

DOOR MONITOR

SWITCH N/C

CRASH

BAR

- +

STANDARD

MAG LOCK

RED
BLACK

GREEN

WHITE

ORANGE

BROWN
YELLOW

BLUE
SHIELD

RED
BLACK

GREEN
WHITE

ORANGE
BROWN

YELLOW
BLUE

SHIELD

W

H

IT

E

/B

L

U

E

B

L

U

E

G

N

D

READER

READER

LAN / WAN /

INTERNET

NOTES, UNLESS OTHERWISE SPECIFIED:

REVISION HISTORY

REV

ECO #

DESCRIPTION

1. THIS VERTX INSTALLATION WIRING DIAGRAM IS INTE NDED AS AN EXAMPLE ONLY, AND SHOULD NOT BE INTERPRETED AS AN HID CORPORATION RECOMMENDATION.

2. THE V1000 PHYSICAL RS-485 PORT 1 AND 2 RESIDE ON LOGICAL BUS 1 (P3), WHILE PORT 3 AND 4 RESIDE ON RS-485 LOGICAL BUS 2 (P4).

3. THE TERMINATION JUMPER SHOULD BE IN THE "OUT" POSITION FOR ALL V100 SERIES PANELS EXCEPT FOR THE LAST V100 SERIES PANEL ON THE RS-485 RUN. THE

LAST V100 SERIES PANEL MUST HAVE THE TERMINATION JUMPER IN THE "IN" POSITION.

4. THE DEFAULT SETTINGS FOR ALL VERTX INPUT DEVICES ARE NORMALLY OPEN (N/O), EXCEPT DOOR MONITOR INPUT WHICH IS NORMALLY CLOSED (N/C).

5. THIS NUMBER INDICATES THE INTERFACE ADDRESS OF THE VertX UNIT. (DASH NUMBER NOT PRINTED ON ACTUAL COVER).

DO NOT DUPLICATE ADDRESSES ON THE SAME BUS.

6. SUPPORTS UP TO (ANY COMBINATION OF) 32 INTERFACE PANELS. SEE THE QUICK INSTALL GUIDE FOR DETAILS.

V1000 - ACCESS

CONTROLLER

(REQUIRED)

SEE NOTE 6

V100 - DOOR/READER INTERFACE

CARD IN / FREE OUT

(MOST COMMON OPTION)

V200 - INPUT

MONITOR INTERFACE

(OPTIONAL - ADDITIONAL MONITORING)

V100 - DOOR/READER INTERFACE

CARD IN / CARD OUT

(LESS COMMON OPTION)

TO ENCLOSURE

TAMPER SWITCH

TO AC FAIL MONITOR

CONTACTS ON POWER

SUPPLY

TO BATTERY FAIL MONITOR
CONTACTS ON POWER SUPPLY

TO 12 VDC POWER SUPPLY

HID

HID

HID

HID

SEE NOTE 2

SEE NOTE 2

SEE NOTE 5

SEE NOTE 5

SEE NOTE 5

SEE NOTE 3

SEE NOTE 3

SEE NOTE 3

022311

LDixon

USB

CAUTION: Some magnetic locks exhibit both high
inrush current when activated and a high
instantaneous break voltage whende-energized
due to magnetic field collapse. It is recommended
you use of a snubber circuit across the
controlling relay terminals to protect the
controlling relay contacts. Go to
support.hidglobal.com, see Solution 891 - How do
I wire a High In-Rush Current locking device to
VertX/Edge/Edge Solo?.

+

-

TAMPER

+ -

AC

FAIL

+ -
BAT
FAIL

- +

+12-24VDC

IN

(Input 6) (Input 7)

WARNING: VertX EVO V1000 is a
NON-PoE device. DO NOT connect J1
(Ethernet port) to a PoE capable port.
This applies to both direct PoE Power
Sourcing Equipment (Endspan PSE) and
PoE injector (Midspan PSE) equipment.
Not all PSE's correctly detect Non-PoE-
capable devices, and such PSE's may not
function as expected when connected to
Non-PoE equipment.
Installation Note: Carefully peel the
attached Warning Label from the bottom
of the unit and leave the label attached to
the unit's cover for future reference.

Advertising