Installation, Figure 4 - alarm installation – Aico Ei261DENRC User Manual

Page 15

Advertising
background image

15

4. INSTALLATION

The Alarm is designed to be permanently
mounted, using its own built-in terminal
block to connect it to the mains wiring. The
mounting plate can be screwed directly to
the ceiling/wall. Alternatively it can be
screwed to a standard junction box (BS
4662 single gang accessory box). The alarm
requires a current of 60mA. The Alarm must
not be exposed to dripping or splashing.
There are important markings on the
underside of the alarm.

IMPORTANT PRECAUTION: Do not install
the actual alarm itself in new or
renovated buildings until all work is
completed (including floor coverings)
and the building has been fully cleaned.
The wiring can be installed when
appropriate. (Excessive dust and debris
from building work can contaminate the
sensor and cause problems, it will also
invalidate the guarantee). If it must be
installed, cover it completely, particularly
around the edges, with a suitable
covering, until all cleaning is finished.

LOCATION FOR
TAMPERPROOF SCREW
(see page 16)

PUSH SMALL SCREWDRIVER

STRAIGHT IN TO RELEASE.

PUSH COVER AWAY FROM

SCREWDRIVER

WARNING: DISCONNECT MAINS BEFORE REMOVING ALARM FROM

CEILING OR WALL

TAMPERPROOF CATCH

MOUNTING PLATE

SIDE VIEW

GAS ENTRY HOLES

Figure 4 - Alarm Installation

B16132-R0-261ENRC-UC-ENG 7/11/07 11:52 AM Page 15