Electric Fryer Operation & Care Manual • 9

I N S T A L L A T I O N

An electrical wiring diagram is located in the front

access door of the fryer. The fryer must be installed by a

qualified electrician. This appliance must be branch circuit

protected with proper ampacities, in accordance with

the wiring diagram located in the fryer. The fryer must

be properly grounded in accordance with the National

Electrical Code and applicable local codes. A means to

disconnect the unit must be incorporated into the fixed

wiring in accordance with wiring codes.
Wire size for the main incoming power to the unit must

match the minimum size listed in the specifications

applicable to the specific fryer. For supply connections,

locate the wire size posted on the label located on the

electrical control box cover, behind the service panel or

elsewhere listed in this manual.
Before operating the fryer, check all cable connections

in the electrical connection area for tightness since

connections can loosen during transport.

230V:

To prevent an electrical shock hazard between the

appliance and other appliances or metal parts in close

vicinity, an equalization-bonding stud is provided. An

equalization bonding lead must be connected to this

stud and the other appliances / metal parts to provide

sufficient protection against potential difference. The

terminal is marked with the following symbol.

ELECTRICAL - ASF-60E

voltage

phase

cycle

/

hz

amps

kW

awg

208-220

(agcy)

3

60

47.0

17.9 aWg 6

at 208

3

60

45.0

16.2 aWg 6

at 220

3

60

47.6

18.2 aWg 6

240

(agcy)

3

60

43.0

17.9 aWg 6

380-415

at 380

3

50

20.4

15.4 aWg 10

at 415

3

50

25.4

18.3 aWg 10

440-480

(agcy)

3

60

21.8

18.1 aWg 10

at 440

3

60

20.4

15.5 aWg 10

at 480

3

60

22.2

18.5 aWg 10

No cord or plug

D A N G E R

To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code ANSI/
NFPA No. 70. In Canada, all electrical
connections are to be made in
accordance with CSA C22.1, Canadian
Electrical Code Part 1 or local codes.

D A N G E R

ENSURE POWER SOURCE
MATCHES VOLTAGE STAMPED
ON APPLIANCE NAMEPLATE.

E L E C T R I C A L R E Q U I R E M E N T S

ELECTRICAL - ASF-75E

voltage

phase

cycle

/

hz

amps

kW

awg

208-220

(agcy)

3

60

68.2

26.0

AWG 2

at 208

3

60

66.6

24.0

AWG 2

at 220

3

60

70.8

27.0

AWG 2

240

(agcy)

3

60

66.8

27.8

aWg 2

380-415

(agcy)

3

50

38.1

27.5

aWg 6

at 380

3

50

35.2

23.2

aWg 6

at 415

3

50

38.2

27.5

AWG 6

440-480

(agcy)

3

60

31.3

26.0

aWg 8

at 440

3

60

30.7

23.5

AWG 8

at 480

3

60

33.4

27.9

AWG 8

No cord or plug

D A N G E R

APPLIANCES WITH NO CORD
PROVIDED BY FACTORY MUST
BE EQUIPPED WITH A CORD OF
SUFFICIENT LENGTH TO PERMIT
THE APPLIANCE TO BE MOVED
FOR CLEANING.
ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
APPLICABLE ELECTRICAL CODES.

Hard wired models:
Hard wired models must be equipped with a

country certified external allpole disconnection

switch with sufficient contact separation.
If a power cord is used for the connection of the

product an oil resistant cord like H05RN or H07RN

or equivalent must be used.