E-01, E-02, E-10 – Alto-Shaam FRY TECH ASF-60E User Manual

Page 43: E-20, E-30, E-31, E-86, Nocomms

Advertising
background image

Electric Fryer Operation & Care Manual • 41

D E L U X E C O N T R O L O P E R A T I O N

ERROR CODE DISPLAY MESSAGES

probable

cause

Ambient temperature surrounding the
controller is too high or too low.

Controller EEPROM initialization
(

first

time

use

).

Probe shorted.

Probe open.

Exceeded maximum amount of time to
achieve temperature.

Exceeded set temperature by X degrees.

Preset Data Error (EEPROM data error)

Problem with connectors or cable.

TEMPERATURE VERIFICATION

The temperature of the cooking oil/shortening and the temperature set-point can be

verified at any time.

Press the “Temperature” key once to verify the temperature of the oil/shortening.
Press the “Temperature” key twice to verify the set-point temperature.

The fryer control will automatically exit either of these readings after four (4) seconds.

If a defective probe is suspected, measure the temperature of the oil/shortening with a
thermometer. Compare the thermometer reading with temperature shown in the control to
make certain the readings are reasonably close. If there is a wide discrepancy, perform a
complete fryer shutdown and contact Alto-Shaam service.

E-01

AMBIENT

E-02

DEFAULTS

E-10

FIXPROBE

E-20

FIXPROBE

E-30

LOWTEMP

E-31

HITEMP

E-86

SERVICE

NOCOMMS

SERVICE


solution

Adjust the system or the environment so that the ambient
air surrounding the control is above 32°F (0°C) or below
160°F (80°C).

Wait for approximately 30 to 120 seconds. If the message
does not terminate, return the controller to the factory.

Contact Alto-Shaam service.

Contact Alto-Shaam service.

Turn power

OFF

and reset the control.

Turn power

OFF

and allow fryer to cool.

Contact Alto-Shaam service.

Contact Alto-Shaam service.

Check ribbon cable from main board to slave board.
Contact Alto-Shaam service.