Electric Fryer Operation & Care Manual • 39

D E L U X E C O N T R O L O P E R A T I O N

PROGRAMMING THE CONTROL

“FILTER CNT” The filter count program allows the operator to change the number of processed fry

loads within a range of 5 to 15 before the monitor notifies the operator to service the oil/
shortening. The factory default is set at 15 loads.

THE

“FILTER”

MONITOR

PROGRAM

MUST

BE

ACTIVATED

IN

ORDER

TO

MAKE

THE

“FILTER CNT”

PROGRAM

FUNCTIONAL

.

Press the Up

or Down

arrow keys to scroll until “FILTER CNT” appears in the display. Press

the Right

4

arrow key to enter the program. Display stops flashing. Press the Up

or Down

arrow keys to until the desired number of processed loads appears in the

display. When the desired setting appears, press the Right

4

arrow key to accept the

selection. Display flashes. Press the Down

arrow key to advance the control to the

next programming function.

“MAX TIME”

“MAX TIME”

provides notification when the temperature of the oil is

lower than the set-point temperature. The factory set default is 3 minutes
and should not be adjusted by the operator. Press the down

arrow

key to advance the control to the next programming function.

“HI TEMP”

“HI TEMP”

allows the operator to trigger an automatic fryer shut-down at a specified

oil temperature within a range of 250°F to 450°F (121°C to 232°C). This safety feature is
provided in the event the actual oil temperature exceeds the oil set-point
temperature due to equipment malfunction. The factory default is set at
450°F (232°C).

Press the Up

or Down

arrow keys to scroll until “HI TEMP” appears in the display. Press

the right

4

arrow key to enter the program. Display stops flashing. Press the Up

or

Down

arrow keys to scroll until the desired shut-down temperature appears in the

display. When the desired temperature appears, press the right

4

arrow key to accept the

selection. Press the down

arrow key to advance the control to the next

programming function.

3 : 0 0

Max Time

LoTemp

HOT

4 5 0

° F

Hi Temp

1 5

Filter Cnt

Advertising