Sony STR-DN1030 User Manual

Page 42

Advertising
background image

42

US

D:\NORM'S JOB\SONY HA\SO130039\STR-DN1030_PMRF
06\4420297142_US\US04GET_STR-DN1030-CEL.fm

masterpage: Left

STR-DN1030

4-420-297-14(2)

3

Press

V/v repeatedly to select

“Auto Cal.”, then press

or

b.

4

Press

B/b repeatedly to select

“Start”, then press

.

5

Press

to select “START”.

6

The measurement starts in five
seconds.

The measurement process will take
approximately 30 seconds with a test
tone.
When the measurement ends, a beep
sounds and the screen switches.

Note

If an error code appears on the screen, see
“Message list after Auto Calibration
measurement” (page 44).

7

Press

V/v repeatedly to select

the item you want, then press

.

Retry: Performs the Auto Calibration

again.

Save: Save the measurement results and

exits the setting process.

Warning: Displays warning related to

the measurement results. See “Message
list after Auto Calibration
measurement” (page 44).

Exit: Exits the setting process without

saving the measurement results.

8

Save the measurement result.

Select “Save” in step 7.

Notes

• The A.P.M. (Automatic Phase Matching)

function is activated after you save the
measurement result.

• The A.P.M. function does not work in the

following cases.
– The calibration type is set to “Off” when

using the “Cal. Type” Auto Calibration

(page 42).

– When Dolby TrueHD or DTS-HD signals

with a sampling frequency of more than
48 kHz are being received.

9

Press

B/b repeatedly to select

“Cal. Type”, then press

.

Full Flat: Makes the measurement of

frequency from each speaker flat.

Engineer: Sets to “the Sony listening

room standard” frequency
characteristics.

Front Reference: Adjusts the

characteristics of all the speakers to
match the characteristics of the front
speaker.

Off: Sets the Auto Calibration equalizer

level and the A.P.M. function to off.

Tip

You can select the calibration type after you
have performed the Auto Calibration and
saved the settings.

Advertising