Step 3: (gas dryer only) connect gas supply pipe, Warning – Alliance Laundry Systems 512685R2 User Manual

Page 17

Advertising
background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Installation

15

512685

A Backdraft Damper, Part No. 58786 (obtain locally),
should be installed in a 4 inch (10.2 cm) diameter
VERTICAL duct system. This will prevent a backdraft
when dryer is not in use, and will keep the exhaust air
in balance within the central exhaust system.

Step 3: (Gas Dryer Only) Connect Gas
Supply Pipe

1. Make certain your dryer is equipped for use with

the type of gas in your laundry room. Dryer is
equipped at the factory for Natural Gas with a
3/8 inch NPT gas connection.

NOTE: The gas service to a gas dryer must
conform with the local codes and ordinances, or in
the absence of local codes and ordinances, with the
latest edition of the National Fuel Gas Code ANSI
Z223.1/NFPA 54 or the CAN/CGA-B149, National
Gas Installation Code.

Natural Gas, 1000 Btu/ft

3

(37.3 MJ/m

3

) service must

be supplied at 6.5 ± 1.5 inch water column pressure.

For proper operation at altitudes above 2000 feet
(610 m) the natural gas valve spud orifice size must be
reduced to ensure complete combustion. Refer to
Table 2.

2. Remove the shipping cap from the gas

connection at the rear of the dryer. Make sure you
do not damage the pipe threads when removing
the cap.

Duct

Station

Minimum Diameter of

Collector Duct

A

4 inches (10.2 cm)

B

8 inches (20.3 cm)

C

9 inches (22.9 cm)

D

10 inches (25.4 cm)

E

11 inches (27.9 cm)

F

12 inches (30.5 cm)

G

13 inches (32.6 cm)

H

14 inches (35.6 cm)

I

15 inches (38.1 cm)

J

15 inches (38.1 cm)

K

16 inches (40.6 cm)

To reduce the risk of gas leaks, fire or
explosion:
• Each dryer must be connected to the type

of gas as shown on nameplate located in
the door recess.

• Use a new flexible stainless steel

connector.

• Use pipe joint compound insoluble in L.P.

(Liquefied Petroleum) Gas, or Teflon tape,
on all pipe threads.

• Purge air and sediment from gas supply

line before connecting it to a dryer. Before
tightening the connection, purge
remaining air from gas line to each dryer
until odor of gas is detected. This step is
required to prevent gas valve
contamination.

• Do not use an open flame to check for gas

leaks. Use a non-corrosive leak detection
fluid.

• Any disassembly requiring the use of

tools must be performed by a suitably
qualified service person.

W315

WARNING

Natural Gas Altitude Adjustments

Altitude

Orifice Size

Part

Number

feet

m

#

inches

mm

2,000

610

41

0.0960

2.44

503776

3,000

915

42

0.0935

2.37

503777

5,500

1,680

43

0.0890

2.26

503778

7,000

2,135

44

0.0860

2.18

58719

9,000

2,745

45

0.0820

2.08

503779

10,500

3,200

46

0.0810

2.06

503780

Table 2