Signal Wiring

Connecting an External Bell or Horn Relay

If external signal(s) are required, the addition of a relay (not supplied) will be necessary.

When a signal is activated, the internal contacts close completing the circuit. These internal
contacts are “dry” and supply no voltage. Voltage applied to these contacts must not exceed 30
volts. An external relay must be used to activate signaling devices.

Acroprint Relay

An Acroprint Relay Part Number 01-0230-000 should be used for external signal(s).

Connections Shown for Acroprint Relay Part Number 01-0230-000

Please consult your local electrician for installation, safety, and compliance to
local codes and regulations.

Be sure to unplug the unit from the wall outlet before wiring. Improper connection
may cause a malfunction of the unit. Also make sure to secure wires with the wire
clamp.