Asus RS100-E5-PI2 User Manual

Page 120

Advertising
background image

6-26

Chapter 6: RAID Configuration

3. When prompted, use the arrow keys to select Yes from the Consistency

Check dialog box, then press <Enter>. You may also press <F10> to check

the drive consistency.

A progress bar appears on screen.

4. While checking the disk consistency, press <Esc> to display the following

options.
Stop: Stops the consistency check. The utility stores the percentage

of disk checked, When you restart checking, it continues from the last

percentage completed rather than from zero percent.

Continue: Continues the consistency check.
Abort: Aborts the consistency check. When you restart checking, it

continues from zero percent.

5. When checking is complete, press any key to continue.

LSI Software RAID Configuration Utility Ver A.53 Sep 06, 2007

SPACE-(De)Select, F10-Check Consistency

Management Menu

Configure

Initialize

Objects

Rebuild

Check Consistency

Virtual Drive(s) Configured

LD RAID Size #Stripes StripSz Status

0 10 154494MB 4 64 KB ONLINE

Virtual Drives

Virtual Drive 0

Consistency Check?

Yes

No

Select VD

LSI Software RAID Configuration Utility Ver A.53 Sep 06, 2007

SPACE-(De)Select, F10-Check Consistency

Management Menu

Configure

Initialize

Objects

Rebuild

Check Consistency

Virtual Drive(s) Configured

LD RAID Size #Stripes StripSz Status

0 10 154494MB 4 64 KB ONLINE

Virtual Drives

Virtual Drive 0

CC Under Process

VD 0 Consistency Check. Press Esc to Abort.

¦ 85 % Completed

The Data On The Drives Is Inconsistency. Repair Done!