6.3.4

Checking the drives for data consistency

You can check and verify the accuracy of data redundancy in the selected virtual

drive. The utility can automatically detect and/or detect and correct any differences

in data redundancy depending on the selected option in the Objects > Adapter

menu.

The Check Consistency command is available only for virtual drive included in

a RAID 1 set.

Using the Check Consistency

To check data consistency using the Check Consistency command:

1. From the Management Menu, select Check Consistency, then press

<Enter>.

2. The screen displays the available RAID set(s) and prompts you to select the

virtual drive to check. Press the <Spacebar> to select the virtual drive from

the Virtual Drive selection, then press <F10>.

LSI Software RAID Configuration Utility Ver A.53 Sep 06, 2007

Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option

Management Menu

Configure

Initialize

Objects

Rebuild

Check Consistency

CC Of VD(s)

LSI Software RAID Configuration Utility Ver A.53 Sep 06, 2007

SPACE-(De)Select, F10-Check Consistency

Management Menu

Configure

Initialize

Objects

Rebuild

Check Consistency

Select VD

Virtual Drive(s) Configured

LD RAID Size #Stripes StripSz Status

0 1 154494MB 2 64 KB ONLINE

Virtual Drives

Loical Drive 0