Asante Technologies 1012 User Manual

Page 23

Advertising
background image

Page 1-11

Quick View

Set the switch on all other hubs in the daisychain to the

UP

position.

Only one hub at the end of the daisychain can have this
switch down. All others hubs in the chain must have it up.

PC/Terminal DIP Switch

This switch controls the configuration for the Bridge/Hub
RS232 port and the AMS out-of-band link ports. How you set the
switch depends on how you connect your Macintosh or PC run-
ning AsantéView Out-of-Band.

If you are running AsantéView Out-of-Band and your Asanté
Management Station is connected to the Bridge/Hub RS232
port, set this switch

UP

. The PC/Terminal switches on all other

hubs in the out-of-band daisychain must be set

DOWN

.

If you want to use the Bridge/Hub RS232 port for local manage-
ment, set this switch

DOWN

.

If you are running AsantéView Out-of-Band and your Asanté
Management Station is connected to the AMS Link port, set this
switch

DOWN

on all hubs on the out-of-band daisychain

.

Fan

This is a small cooling fan for the AsantéBridge 1012. The fan
should turn on when the unit is powered on. Do not operate
the hub if the fan does not come on.

AC Power Connector

Plug the AC power cord into this connector.

AC Line Fuse

The AC fuse for the unit is behind this cover plate. You must
remove the plate to access and replace the fuse.

Included in each hub is a spare fuse. To access the spare fuse,
pry out the fuse holder with a flathead screwdriver. With some
units, this can take extra effort. The fuse holder slides straight
out from the back of the Hub. The spare fuse is in a small black
box inside the fuse holder. To open, push out from one end.

On/Off Switch

Turns the AsantéBridge 1012 on and off.

Advertising