Page 2-21

Connecting a VT100 Terminal

The bridge can be configured and monitored through a direct
serial connection to the bridge RS232 port on the rear of the
bridge unit.

The bridge functions as a DCE; the terminal must be DTE.

You must use an RS232 straight-through serial cable to connect
the bridge serial port to your Macintosh or PC. The bridge connec-
tor requires a male DB9; a Macintosh requires a DIN8, and PCs
may require DB9, DB15, or DB25 connectors.

Figure 2-13 Connecting the VT100 terminal

Important:

Do not connect the VT100 to the

hub RS232

port

located below the bridge local management port.

This

port is used only for connecting AsantéView Out-

of-Band.

The bridge local management port data communication parame-
ters are preset at the factory and cannot be modified. You must set
up your terminal or emulation software to match these parame-
ters:

Table 2-1 Local management port parameters

Parameter

Setting

Baud rate

9600

Data bits

8

Stop bits

1

Parity bit

None

Handshaking

None

Connecting a

VT100 Terminal

RJ21 10 BASE-T PORTS

IN or

OUT

AUI

PARTITION
TRAFFIC

RS232

THROUGH

AMS LINK

UP=PC

DOWN=TERMINAL

END

3-IN-1 UPLINK

BNC

Spare Fuse in Fuse Holder

2A/250V Slow Blow Fuse

Replace Only With Fuse of Same Rating

Bridge AUI Port

Bridge Local Management
RS 232 Port

DB 15 Male
RS 232 Connector

To VT100 terminal,
PC COM port, or
Macintosh modem
port