Page 3-34

Chapter 3 — AsantéBridge 1012 Local Management

Each range within the set acts as a filter in a pipeline. A packet has
to get past all three filters to completely traverse the pipeline and
be forwarded (or discarded, according to how the filter mode is
set).

Figure 3-20 Bridge Filtering Table

As many as ten range entries can be stored in the table.

Incoming packets are checked against this table

after

they are

checked against the forwarding table.

Exit

returns you to the

Bridge Parameters Menu.

Next/Prev Page

moves you one page forward or back-

ward in the table.

Filtering Mode

sets up how the entire table filters: If set

to

FORWARD

only packets defined by the

type

field

with Ethernet addresses falling within ranges defined in
the table are forwarded

if the Status for the range is

turned ON

. All other packets are discarded.

If Filtering Mode is set to

DISCARD

the reverse is true:

Packets defined by Type and address within this entry
will be discarded

if the Status for the range is turned

ON

.

DST Address

defines a range of addresses for the

devices allowed to have this packet forwarded to the
specified devices.

SRC Address

defines a ranges of addresses for the send-

ing devices allowed to forward packets to the devices
defined in the

DST Address

field.

Type

defines the packet or protocol type to be for-

warded or discarded.

Advertising