Hardware and Software Design • Manufacturing Services

P a g e 14

SCC Tx A

OUT_4 (188)

SCC Rx A

AUX_IN_0 (enhanced hysteresis 188)

SCC Rx Clk

AUX_IN_1 (enhanced hysteresis 188)

SCC RTS A

AUX_OUT_0 (open drain)

SCC Tx B

IO_15 (RS422)

SCC Rx B

IO_13 (RS422)

When test mode select is “10” the following changes are made (if a signal
is not listed here, its connection remains the same):

Signal Function

Driver/Receiver

UART Rx A

IO_1 (RS422)

UART Rx B

IO_3 (RS422)

UART Rx C

IO_5 (RS422)

UART Rx D

IO_7 (RS422)

SCC RTS A

AUX_OUT_1 (open drain)

SCC Tx B

IO_14 (RS422)

SCC Rx B

IO_12 (RS422)

When test mode select is “11” the following changes are made:

Signal Function

Driver/Receiver

UART Rx A

IN_0 (RS232)

UART Rx B

IN_1 (RS232)

UART Rx C

IN_2 (RS232)

UART Rx D

IN_3 (RS232)

When test mode select is “01” the following changes are made:

Signal Function

Driver/Receiver

UART Rx A

IN_4 (RS232)

UART Rx B

IN_5 (RS232)

Advertising