Drive operating conditions, Led indicators – ADIC 4000 User Manual

Page 46

Advertising
background image

5-6

Operation and Maintenance

62-0162-01

POST completes in about 13 seconds and the drive responds normally to all ommands.
However, it may take longer for the media to become ready.

Drive Operating Conditions

LED Indicators

Use Table 5-3 on page 5-6 to determine the drive’s operating
condition.

Table 5-3

Operating Condition Indications

Right Indicator Panel LED

Label

Color

State

Operating Condition

Write Protected

Orange

ON
OFF

Tape is write-protected.
Tape is write-enabled.

Tape in Use

Yellow

Blinking
ON

Tape is moving.
Tape is loaded; ready for use.

Use Cleaning Tape

Yellow

ON
Remains on
after unloading
cleaning tape
After cleaning,
turns on again
when reloading
data cartridge

Drive head needs cleaning,
or the tape is bad.
Cleaning attempted, but tape
expired, so cleaning not
performed.
Problem data cartridge. Try
another cartridge.

Operate Handle

Green

ON
OFF
Blinking

OK to operate the Cartridge
Insert/Release Handle.
Do not operate the Cartridge
Insert/Release Handle.
Drive was powered on with
door open. Close door and
let drive complete
initialization.

All Right Indicator
Panel LEDs or,
All Left Indicator
Panel LEDs

-

ON
Blinking

POST is starting.
An error has occurred.

Advertising
This manual is related to the following products: