ADIC 4000 User Manual

Page 76

Advertising
background image

B-6

Drive Configuration

62-0162-01

Figure B-6

TRM PWR/TRM ENB Jumper Position

If . . .

And . . .

Then You Should . . .

Another device is
providing
terminator power

The 4000/7000DLT
Series is not at the
end of the SCSI bus
chain

Connect jumpers as

1

in Figure B-6.

Another device is
providing
terminator power

The 4000/7000DLT
Series is at the end
of the SCSI bus
chain

Connect jumpers as

2

in Figure B-6.

No other device on
the SCSI bus is
providing
terminator power

The 4000/7000DLT
Series is not at the
end of the SCSI bus
chain

Connect jumpers as

3

in Figure B-6.

No other device on
the SCSI bus is
providing
terminator power

The 4000/7000DLT
Series is at the end
of the SCSI bus
chain

Connect jumpers as

4

in Figure B-6.

1

N o Term Pow er
D isable Active Termination

2

N o Term Pow er
Enable A ctive Termination

3

Term Pow er
D isable A ctive Termination

4

Term Pow er
Enable A ctive Termination