Troubleshooting, Vertical contact toaster – Antunes, AJ VCT-1000 User Manual

Page 15

Advertising
background image

15

P/N 1010807 Rev. E 06/06

VERTICAL CONTACT TOASTER

TROUBLESHOOTING

WARNING

To avoid possible personal injury and/or damage to the unit, inspection, test and repair of electrical equipment

should be performed by qualified service personnel. The unit should be unplugged when servicing, except when

electrical tests are required. Use extreme care during electrical circuit tests. Live circuits will be exposed.

Problem

Possible Cause

Corrective Action

No heat and conveyor

belts do not move.

Toaster is installed incorrectly.

Perform the installation and operating proce-

dures found in the Installation and Operation

sections of this manual.

Inoperable power cord or Rocker

Switch.

Check receptacle for correct voltage (see the

Specifications section of this manual).

If necessary, contact your maintenance person

or Authorized Service Agency for service.

Hi-Limit Control is tripped.

Reset the Hi-Limit Control (see Figure 6 in the

Operations section of this manual).

Wiring Problem.

Contact your maintenance person or Authorized

Service Agency for service.

No heat but Conveyor

Belt Chains move.

Wiring Problem.

Contact your maintenance person or Authorized

Service Agency for service.

Inoperative Platen.
Inoperable Thermostat

Platen is hot but

Conveyor Belt Chains do

not rotate.

Heat Shield not installed.

Install Heat Shield (Figure 2)..

Conveyor Safety Interlock switch not

activated by the heat shield..

Re-install the Heat Shield correctly so that the

Heat Shield applies appropriate pressure on the

Conveyor Safety Interlock switch.

Spring Tensioner Assembly or Roller

Tensioner is damaged or missing.

Replace Spring Tensioner or Roller Tensioners if

damaged or missing.

Conveyor Belt Chain links too loose. Adjust Conveyor Belt Chain length as described

in the Maintenance section of this manual.

Inoperable Drive Motor.

Contact your maintenance person or Authorized

Service Agency.

Loose Drive Motor Sprocket

Setscrew.
Drive Motor Chain has fallen off

sprocket(s).
Inoperable Safety Interlock Switch.

Conveyor Belts Chains

hesitate to rotate and/or

“skip” on sprockets.

Conveyor Belt Chains installed incor-

rectly.

Install Conveyor Belt Chains to match Figure 11.

Be sure that the ends of the hooks are facing

down.

Conveyor Belt Chains too loose.

Adjust Conveyor Belt Chain length as described

in the Maintenance section of this manual.

Spring Tensioner Assembly or Roller

Tensioner is damaged or missing.

Replace Spring Tensioner Assembly or Roller

Tensioners if damaged or missing.