ChannelMag

Section 2 Installation

2.6 Cable Types

Exciter Coils

Electrodes

Reference Coils

Black to 4

Black to 24

Black to 31

White to 5

White to 25

White to 32

Shield to 6

Shield to 26

Shield to 19

The junction box is submersible and is potted with a re-enterable gel,

but is not intended to be

installed in the media flowing in the channel. Cables from dual sensors are wired in the junction

box as shown below in Section 2.6.2.

ChannelMags are connected to a junction box normally using cables in flexible 1” (25mm)

conduit. See the ChannelMag Sensor Specification for the standard cable and conduit lengths.

The cables and conduit are stowed for packing against the side of the Magnetic Enhancement Plates

and are marked “coils,” “electrodes,” and “reference.” The cables from the junction box to the

transmitter are without conduits and connected to the remote transmitter terminals as follows (see

separate instructions for the transmitter):