ChannelMag

Section 2 Installation


For multiple ChannelMag systems, the electrode and reference cables may all run in the same

conduit to their respective transmitters, but separated from the exciter coil cables by a minimum of

2 feet (0.5m). Multi-exciter coil cables may all run together in a single conduit, even with other

power cables. Again, the multi-exciter coil cables must be separated from the reference and

electrode cables by a minimum of 2 feet (0.5m).

The calibration data is provided on the NIST traceable Calibration Certificate, as well as on a label

inside the 4411e transmitter. Details of adjustments in a fl ow range are provided in the 4411e

instruction manual.

3.1 Calibration and

Range Factors

Advertising