HOUNO CM ovens User Manual

Page 30

Advertising
background image

30

: Oven sensor defective
Possible cause:
The temperature sensor in the oven chamber is defective.
The oven cannot be operated until the defect has been remedied.
Remedy: Replace sensor.

: Core temperature probe defective or wrongly fitted
Possible cause:
Probe is not fitted in socket. Probe defective, socket for probe defective or short-
circuited (due to water or fat).
The program cannot be used until the defect has been remedied.
Remedy: Check that the probe is correctly fitted or clean the socket.

: Temperature sensor in steam generator defective
The program cannot be used until the defect has been remedied. However, programs that do not
require the use of the steam generator can still be used.
Remedy: Replace heating element with sensor.

: Condensation sensor defective
The oven can still be operated even if the defect is not remedied. However, the temperature in the
drain will exceed 60°C and the defect should therefore be remedied as soon as possible.
Remedy: Replace sensor.

: Water shortage in steam generator
The maximum water level in the steam generator has not been reached after 2 minutes of filling.
Possible cause: Solenoid valve or dirt filter clogged, water supply blocked or water pressure too
low (min. 1.5 bar). The program cannot be used until the defect has been remedied.
Remedy: Clean solenoid valve or dirt filter. Check the water supply to the oven. Check that the
water pressure is min. 1.5 bar.

: Temperature in steam generator above 130 °C
The temperature of the upper heating element in the steam generator is above 130°C.
Possible cause: Water shortage in steam generator or scale on heating elements.
The program cannot be used until the defect has been remedied.
Remedy: Stop the oven for approx. 5 min., then resume the program that was interrupted.

: Breaking of phase
Possible cause:
One or more phases in the power transmission to the oven is lacking, possibly due
to a defective fuse. The program cannot be used until the defect has been remedied.
Remedy: Check switchboard. Replace defective fuses, if any.

Advertising