HOUNO CM ovens User Manual

Page 6

Advertising
background image

6

The control lamp in the left-hand corner lights while the heating elements are active. See (7) for
checking of temperature in oven chamber.

(6) Oven chamber temperature

The temperature range depends on the operating mode chosen:-

•HOT AIR

20 - 250°C

•COMBI STEAMING

20 - 250°C

•REGENERATING

110 - 160°C

•STEAMING

20 - 100°C

•FORCED STEAMING

105 - 120°C

•PROVING

20 - 40°C

The temperature can be changed any time during the program.

(7) Checking key: Actual oven chamber temperature

You can check the actual temperature any time by pressing (7). The actual temperature is
shown as long as the key is pushed.

(8) Display for core temperature

When the core temperature is activated, this is indicated in the display. When the steamer is off,
the pre-set core temperature is shown; when the steamer is on, the actual core temperature is
shown.

(9) Core temperature

The core temperature can be set between 20 and 99°C.

(10)ON/OFF core temperature control

Activate and deactivate the core temperature by pressing (10).

(2) HOT AIR

Activate the HOT AIR operating mode by pressing (2).

The combi steamer is automatically set to the pre-selected value. For changing the pre-setting,
see (19).

Start the steamer by pressing

(16)