HOUNO CV ovens User Manual

Page 10

Advertising
background image

10

program is “locked”, the small dot next to the number will indicate, by flashing, how many
steps have been entered.

Delete the program by pressing key (18) until the program number to be deleted appears. Press
key (19) until the last step is shown - C, for instance. Press the key showing which operating
mode is in use at the moment (steaming, combi steaming or hot air). The display goes out for
one or two seconds. Then press key (19) to go to B and repeat the procedure. Then go to A.
Note: You should delete programs backwards .

Timer function
To activate the timer, press

in a vacant step. If an operating mode has been entered in the

step, you can delete it by pressing the key of this operating mode for one second. Set the time
as usual. Thus, only the time will be activated in this step – not the heat or the fan. This facility
will typically be used in step A when a postponed program start is required.

Alarm signal between steps
If the oven is required to give out a signal when a step is completed, press key

(21)

at the desired step. The control lamp lights. An alarm signal is heard, and the steamer stops
This is very useful if different types of products are prepared in the oven at the same time and
some are ready before others. Can also be used as a preheating step before the products are
placed in the oven. The oven automatically continues to the next step when the door is closed;
it is therefore not necessary to press key (22).

Return to manual operation
To return to manual operation, press (21) when the program number is shown in the display.

(19) Storing key (memory)

This key has two functions:-

A)

Storing changes to pre-selected settings for operating
modes (12) - (17).

B)

Storing settings in the memory (see (18))

Changing pre-selected settings:-

Set the steamer at the desired operating mode (12) - (17).

Adjust the settings for time (2), oven chamber temperature (6) and perhaps core temperature
(9). Furthermore, the fan speed (23) can be set and the exhaust opened or closed (20).

Then store the new setting by pressing the “receipt key” (19). Press the key until a short signal
sounds (approx. 5 sec.).

The humidity level can be changed as follows:-

Press key 13 or 14 (CM) / 13, 14, 15 or 16 (CV) for approx. 5 min. and a figure indicating the
number of seconds between the humidity pulses shows in the display (1). Choose the interval
you require: the shorter the interval, the larger the amount of humidity.

(20) Exhaust

Advertising