Final installation steps, Machine placement, Level and attach to the wall – Power Soak 35351 Skewer Soak INstallation Manual User Manual

Page 24: Seal around the backsplash and screws, Riser anchor installation

Advertising
background image

20

Final Installation Steps

Machine Placement

Position the Skewer Soak so that the back splash rests against the wall
and is placed according to the floor plan or customer’s selected location.
Examine the drain and water supply lines to determine that the plumbing
can be completed when the Skewer Soak is in the final location. Verify that
the plumbing from the faucet and overflow drain (suggested in earlier
sections) can be reached with the sink against the wall.

Level and Attach to the Wall

Using a level, adjust the feet on the Skewer Soak until the front rim and the
rear rim of the sink are level. The sink must also be level front to back.
Locate the wall studs and mark their location on the top edge of the back
splash. Measure down ¾” from the top of the backsplash and then drill ¼”
diameter holes through the back splash in line with the center of the studs.
Use the #10 stainless steel screws (included with the Skewer Soak) to
attach the skewer soak directly to the wall.

Seal around the Backsplash and Screws

Examine the installation to see that the wall and backsplash are clean and
free of dust and oils. Seal the top and sides of the backsplash to the wall
using the clear NSF approved sealant provided with the Skewer Soak.
Seal around the screw heads to be sure they do not allow water to leak
behind the backsplash. Wipe off all excess sealant leaving a smooth,
clean and sanitary bead of sealant on all the edges.

Riser Anchor Installation

Follow the faucet manufacturer’s directions on the assembly of the faucet
and riser. Anchor the riser supports to the wall using the flange plate
provided with the riser assembly. It may be necessary to cut the support
rods to a shorter length in order to fit between the wall and the riser.

Cut the riser support rods
to the proper length and
attach flanges to the wall

Advertising