Power Soak 34201 PRODUCE SOAK OWNER'S MANUAL User Manual

Page 34

Advertising
background image

32

Only a limited number of troubleshooting and repair
procedures may be performed by the facility owner or
manager. Any troubleshooting or repair that requires
the removal of fasteners or that entails electrical
service must not be attempted by anyone other than an
authorized service agency. To obtain the name of a
recommended service agent in your area, please call
the Power Soak Service Department at 800-444-9624.


Symptom

Possible cause

Remedy

Pump motor
will not run

Circuit breaker
accidentally turned off

Circuit breaker tripped




Wall mounted
disconnect is turned
off

Motor thermal
overload tripped







Start capacitor
defective (single
phase motors)

Turn breaker on


Investigate reason for tripping, e.g.
damaged wiring, undersized breaker.
CONTACT POWER SOAK SERVICE OR
AN AUTORIZED SERVICE AGENCY.

Turn disconnect on



Investigate reason for overload tripping,
e.g. debris stuck in pump impeller. If debris
removal requires that you remove any
fasteners, YOU MUST CONTACT POWER
SOAK SERVICE OR AN AUTORIZED
SERVICE AGENCY. Once rectified, reset
thermal overload by pressing button on
bottom of motor junction box.

Replace capacitor. To do this, YOU MUST
CONTACT POWER SOAK SERVICE OR
AN AUTORIZED SERVICE AGENCY.

Advertising