3sp eci fications and installation – TurboChef Technologies G5 User Manual

Page 9

Advertising
background image

3

SP

eCI

fICATIONS

AND

INSTALLATION

Installation Near Open Heat Source

When placing a TurboChef oven near an open heat source (see illustration below), strictly adhere to the

following:
- If the oven is being placed near a grill or stove, a divider must exist between the oven and the

open heat source, with a minimum of 6” (152 mm) between the oven and the divider.

- If the oven is being placed near a fryer, a divider must exist between the oven and fryer, with a

minimum of 12” (305 mm) between the oven and the divider.

- The height of the divider must be greater than or equal to the height of the oven (32.3” or 820 mm).

- Verify the oven location has a minimum 2” (51 mm) clearance on the top and each side.

Installation Near Open Heat Source

Grill

Partition

32.3” (820 mm)

Above Counter Top

6”

(152 mm)

Minimum

12”

(305 mm)

Minimum

Deep Fryer

Cart / Stand

Partition

32.3” (820 mm)

Above Counter Top

TurboChef

G5 Oven

Advertising