Installation:
inside arm. Again check to see “TOP” label is on top of arm and towards fixture end of the arm. Place remaining gasket over t
hreaded rods and
Options are to be installed in the field. DO NOT alter fittings when mounting the fixtures. Recheck all connections and bolts to insure
they will not loosen due to vibration.
Dimensions and specifications on this page are
based on the most current available data and are
subject to change without notice.
Square Pole:
S9 9” Arm (9”L, 5”W, 2”D)
S2 12” Arm (12”L, 5”W, 2”D)
Round Pole:
P9 9” Arm (9”L, 5”W, 2”D)
P2 12” Arm (12”L, 5”W, 2”D)
INSTALLATION INSTRUCTIONS
PES/PEM, VLR/VMR, ASA, AVL
SERIES MOUNTING OPTIONS
(
S9, S2, P9, P2
OPTIONS)
DRAWING NO. A72261 REV B
(BACK SHEET 2)
PART NUMBER 057-71-72261
WARNING
!
Insert the pole mounting plate inside pole or tenon adapter, aligning the 3 mounting holes in plate with the 3 mounting holes provided on
pole. If poles are not pre-drilled, use template #5 as a guide. Slide threaded rods through top and bottom mounting holes in pole and start
to thread the rods into the matching holes in the mounting plate. Three to four full turns is needed. Place one of the enclosed gaskets
over threaded rods and against pole.
On the top of the arm is a label which reads “TOP . . .this end towards fixture.” To mount arm, slide arm over threaded rod using the bolt-
guides inside arm. Again check to see “TOP” label is on top of arm and towards fixture end of the arm. Place remaining gasket over
threaded rods and against mounting arm.
To mount fixture, align the mounting holes (inside of fixture) with the threaded rods protruding through the end of the arm. Insert threaded
rods into fixture, being careful to align gasketing between fixture housing and mounting arm. Install split lockwashers and cap nuts
(furnished) on threaded rods and tighten securely. During this process, be sure the fixture is mounted straight on pole.
Make wiring connections. Because wiring connections are made in the mounting arm, 60°C wire is allowed for supply leads.
MOUNTING
LABEL
GASKET
POLE MOUNTING PLATE
CAP NUT
2 REQUIRED
SPLIT LOCKWASHER
2 REQUIRED
LOCKWASHER
2 REQUIRED
POLE MOUNTING ARM
THREADED ROD
2 REQUIRED
7/8” CONDUIT
ENTRY HOLE