Lubrication – Hawk Industries Spinner Manual 550 HYDRAULIC Serial Numbers 1 to 205 User Manual

Page 22

Advertising
background image

22

Maintenance & Repair

Lubrication

RP

1. Make sure the gear box oil level

reaches the top pipe plug (RP).

2. Check for any oil leakage from

the gear box seal by looking at
the top or the drive shaft.

Lubricant Required

85-90 weight gear oil
SAE #AGMA5

Check Oil Level Once per Month

Reducer Gear Box

MGV

MGF

Grease after overhaul

1.Remove motor grease vent plug

(MGV). Use a grease gun to fill
the air motor gear box at the
motor grease fitting (MGF) until
grease begins to flow from the
vent (MGV).

2. Replace the vent plug (MGV).

Lubricant Required

Lithium Base #2 High Temperature
Grease. Use Lo-Temp Grease in
temperatures -20 deg. F or below.

Air Motor Gear Box

NOTE

Consistent lubrication of the Spinner
increases performance and
componnent life.

Advertising