Adjust door valve detents, Warning – Hawk Industries Spinner Manual 550 HYDRAULIC Serial Numbers 1 to 205 User Manual

Page 30

Advertising
background image

30

Maintenance & Repair

Adjust Door Valve Detents

HDS

Hydraulic Spinmaster

1. Remove the rubber cover and use

a 1/4" Allen Wrench and rotate
the hydralic detent screw
(HDS) at the rear of the hydraulic
valve clockwise to increase
detent
pressure and counter-
clockwise
to reduce detent
pressure. Adjust to a pressure
that assures good holding
strength when shifted to grip on
pipe. Replace the rubber cover.

Air Spinmaster

1. Use a 3/16" Allen Wrench and

rotate the detent screw (PDS) at
the rear of the door valve clock-
wise
to increase detent pressure
and counter-clockwise to re-
duce detent
pressure. Adjust to
a pressure that assures good
holding strength when the door
valve lever is shifted to close the
spinner doors.

PDS

Part Numbers

Part Name

Part #

Hyd. Detent Repair Kit(HDS) 031-VC-RK
Pneu. Detent Repair Kit(PDS) 031-DET-RK

If the hydraulic valve
detent is not maintained on
the Hydraulic and Air
Spinmaster , the unit will
slip while spinning pipe .

WARNING

Advertising