Figure 25: Removing the Bearing Using

Pullers

Figure 26: Removing the Bearing Using a

Universal Kit

8. For 2” frames only: remove the bearing

backup ring. (See Figure 27.) (See Figure 22
for a listing of pump sizes with 2” frames.)

Figure 27: Removing the Bearing Backup Ring

(2” Frames Only)

9. Remove the bearing cap from the shaft.

Remove the slinger.

10. Repeat steps 1 through 9 to remove the

bearing frame on the other side. When
finished, proceed to the appropriate
disassembly procedure depending on the type
of seal in your pump.

11. Remove lip seals from both caps and the

inboard bearing bracket.

DISASSEMBLY PROCEDURE TO REMOVE
STANDARD MECHANICAL SEALS
1. Loosen the set screws in the sleeve.

2. Remove the four gland assembly capscrews.

3. Remove the gland assembly and the sleeve

from the shaft. (See Figure 28.) The use of a
bearing puller attached to the step in the
sleeve may be required.

Figure 28: Removing the Gland Assembly and

Sleeve

4. Remove the gland gasket.

5. While pushing down on the mechanical seal

head, remove the retaining ring from the shaft
sleeve groove. (See Figure 29.)

Figure 29: Mechanical Seal Head and Gland

with Retaining Ring Removed

6. Remove the mechanical seal head from the

sleeve assembly.

7. Remove the gland assembly from the shaft

sleeve.

8. Remove the stationary mechanical seal seat

from the gland bore.

9. Remove the quad ring from the shaft.

Advertising