Bell & Gossett P5002169C Series VSCS User Manual

Page 38

Advertising
background image

36

TO CHANGE STANDARD MECHANICAL
SEALS
See the following sections:

A. GENERAL DISASSEMBLY INSTRUCTIONS

B. DISASSEMBLY PROCEDURE TO REMOVE

BEARING FRAMES – ALL PUMPS

C. DISASSEMBLY PROCEDURE TO REMOVE

STANDARD MECHANICAL SEALS

D. ASSEMBLY PROCEDURE TO INSTALL

STANDARD MECHANICAL SEALS

E. ASSEMBLY PROCEDURE TO INSTALL BEARING

FRAMES – ALL PUMPS

F. GENERAL ASSEMBLY INSTRUCTIONS

TO CHANGE CARTRIDGE SEALS
See the following sections:

A. GENERAL DISASSEMBLY INSTRUCTIONS

B. DISASSEMBLY PROCEDURE TO REMOVE

BEARING FRAMES – ALL PUMPS

C. DISASSEMBLY PROCEDURE TO REMOVE

CARTRIDGE SEALS

D. ASSEMBLY PROCEDURE TO INSTALL

CARTRIDGE SEALS

E. ASSEMBLY PROCEDURE TO INSTALL BEARING

FRAMES – ALL PUMPS

F. GENERAL ASSEMBLY INSTRUCTIONS

TO CHANGE THE PACKING OR SLEEVE
See the following sections:

A. GENERAL DISASSEMBLY INSTRUCTIONS

B. DISASSEMBLY PROCEDURE TO REMOVE

STUFFING BOX AND PACKING

C. ASSEMBLY PROCEDURE TO INSTALL STUFFING

BOX AND PACKING

D. ASSEMBLY PROCEDURE TO INSTALL BEARING

FRAMES – ALL PUMPS

E.

GENERAL ASSEMBLY INSTRUCTIONS

ORDERING PARTS
The pumps covered by this manual have been
designed and built with certain replaceable
wearing parts. The recommended inventory of
spare parts depends upon the installation and the
importance of continued operation.

For normal service, with repairs to be made in the
field, the following parts are recommended for
stock.

ƒ

1 set of bearings

ƒ

1 set of wearing rings (if required)

ƒ

1 set of casing gaskets, quad rings and lip
seals

ƒ

2 mechanical seals (complete)

Parts should be ordered as far in advance of their
use as possible since circumstances beyond the
control of the company may reduce existing stock.
Not all parts are stocked and must be
manufactured for each order.

To facilitate rapid handling of your order for spare
parts, be sure to include the following information:

1. Serial number of the pump. (See the pump

nameplate.)

2. Name of the part.

3. Quantity of each part.

4. Material desired. (Parts will be furnished in

original materials unless specified as a
material change. All material substitutions
should be discussed with the factory.)

DEALER SERVICING
If trouble occurs that cannot be rectified, contact
your local Bell & Gossett representative. The
representative will need the following information
in order to provide assistance:

1. Complete nameplate data of the pump and

motor.

2. Suction and discharge pipe pressure gauge

readings.

3. Ampere draw of the motor.

4. A sketch of the pumping hook-up and piping.