Bell & Gossett P5002169C Series VSCS User Manual

Page 37

Advertising
background image

35

TO CHANGE ROTATION

Figure 52: Impeller to Volute Orientation

WARNING: Unexpected Startup Hazard

Disconnect and lockout power before servicing.

Failure to follow these instructions could result in
serious personal injury or death, or property
damage.

WARNING: Electrical Shock Hazard

Electrical connections to be made by a qualified
electrician in accordance with all applicable codes,
ordinances, and good practices.

Failure to follow these instructions could result in
serious personal injury or death, or property
damage.

WARNING: Rotating Components
Hazard

Do not operate pump without all guards in place.

Failure to follow these instructions could result in
serious personal injury or death and property
damage.

1. Remove the pump from the base.

2.

Follow the Disassembly Procedures
applicable to the pump.

NOTE: Only one of the coverplates must be
removed to change rotation.

3. Press the (press-fitted) impeller off the shaft.

Observe the direction in which the vane tips
are pointing. Turn the impeller end for end
(180°) and press it back onto the shaft. Refer
to the section entitled Assembly Procedure
to Install Coverplates and Shaft Assembly
.
The vane tips should be pointing in the
opposite direction. (See Figure 52.)

4. Reinstall the rotating assembly per the section

entitled Assembly Procedure to Install
Coverplates and Shaft Assembly
. Check the
impeller to volute relationship per Figure 52.

5. Complete the reassembly by following the

procedures applicable to the pump.

NOTE: Unless the motor rotation is reversed the
impeller will run backward. Check the motor for
proper rotation before putting the pump back in
service.