Figure 40: View of the pump interior after one

coverplate has been installed

8. Install the volute capscrews.

NOTE: Refer to Table 6 for all capscrew torque
requirements.

9. Insert the shaft assembly into the volute. (See

Figure 41.) Ensure that the shaft threads are
protected using tape or nuts. (See Figure 34.)

Figure 41: Installing the Shaft Assembly

10. Repeat steps 6 through 8 to install the second

coverplate.

ASSEMBLY PROCEDURE TO INSTALL
STANDARD MECHANICAL SEALS

Figure 42: Standard Mechanical Seal Cross

Section

1. Press the stationary mechanical seal seat into

the gland bore. (See Figure 43.) To ease
assembly, lightly lubricate the bore with P-80
Rubber Lubricant Emulsion, soapy water, or
equivalent.

NOTE: Handle the seals with care. Clean the
glands and seals before assembly. Take care not
to damage the seals during assembly.

Figure 43: The Seal Seat Installed in the Gland

2. Slide the gland assembly over the shaft

sleeve.

3. Lightly lubricate the shaft sleeve with P-80

Rubber Lubricant Emulsion, soapy water, or
equivalent and slide the mechanical seal head
onto the sleeve.

4. While pushing down on the mechanical seal

head, install the retaining ring into the shaft
sleeve groove.

5. Apply anti-seize compound only to the area of

the shaft that will be under the sleeve. (See
Figure 44.)

Figure 44: Applying Anti-seize Compound to

the Shaft

6. Place the gland gasket onto the gland. Grease

may be used to hold the gasket in place. Slide
the complete assembly over the shaft until the
sleeve bottoms out onto the shaft locating
shoulder. (See Figure 45.)