TROUBLESHOOTING

FAILURE TO DISCONNECT AND LOCKOUT ELECTRICAL

POWER BEFORE ATTEMPTING ANY SERVICE CAN CAUSE

SHOCK, BURNS OR DEATH.

SYMPTOM

PROBABLE CAUSE

RECOMMENDED ACTION

MOTOR NOT RUNNING

Motor thermal protector tripped.

Allow motor to cool. Insure minimum pump

submergence. Clear debris from casing and impeller.

Open circuit breaker or blown fuse. Determine cause, call a qualified electrician.

Pump impeller binding or jammed.

Check motor amp draw. If two or more times higher

than listed on pump nameplate, impeller or cutter is

a) Manual operation

Power cable is damaged.

locked, motor bearings or shaft is damaged. Clear

Inadequate electrical connection

debris from cutter casing and impeller, consult with

in control panel.

dealer.

Resistance between power leads and ground should

b) Automatic operation

No neutral wire

read infinity. If any reading is incorrect, call a

connected to control panel.

qualified electrician.

Inadequate electrical connection

Inspect control panel wiring. Call a qualified

in control panel.

electrician.

Defective liquid level switch.

With switch disconnected, check continuity while

activating liquid level switch. Replace switch, as

required.

Insufficient liquid level to

Allow liquid level to rise 3" to 4" (76 mm - 101 mm)

activate controls.

above turn-on level.

Liquid level cords tangled.

Untangle cords and insure free operation.

PUMP WILL NOT

Liquid level cords tangled.

Untangle cords and insure free operation.

TURN OFF

Pump is air locked.

Shut off pump for approximately one minute, then

restart. Repeat until air lock clears. If air locking

persists in a system with a check valve, a

3

16

" (4.8 mm)

hole may be drilled in the discharge pipe approximately

2" (51 mm) above the discharge connection.

Influent flow is matching pump’s

Larger pump may be required.

discharge capacity.

LITTLE OR NO LIQUID

Check valve installed backwards,

Check flow arrow on valve and check valve

DELIVERED BY PUMP

plugged or stuck closed.

operation.

Excessive system head.

Consult with dealer.

Pump inlet plugged.

Inspect and clear as required.

Improper voltage or wired

Check pump rotation, voltage and wiring.

incorrectly.

Consult with qualified electrician.

Pump is air locked.

See recommended action, above.

Impeller is worn or damaged.

Inspect impeller, replace as required.

Liquid level controls defective

Inspect, readjust or replace as required.

or improperly positioned.

PUMP CYCLES

Discharge check valve inoperative.

Inspect, repair or replace as required.

Sewage containment area too small. Consult with dealer.

Liquid level controls defective or

Inspect, readjust or replace as required.

improperly positioned.

Influent excessive for this size

Consult with dealer.

pump.

NOTE: If circuit breaker

“OPENS” repeatedly,

DO NOT reset. Call

qualified electrician.

NOTE: Check the pump in

manual mode first to confirm

operation. If pump operates,

the automatic control or

wiring is at fault. If pump

does not operate, see above.

CONSTANTLY

WARNING

Hazardous

voltage

TROUBLESHOOTING