Hold Current (Percent of Run Current)

Function

SW5

SW6

0%

ON

ON

33%

OFF

ON

66%

ON

OFF

100%

OFF

OFF

Table 6.4

Step Resolution

Function

SW7

SW8

SW9

SW10

Full Step*

OFF

OFF

OFF

OFF

2X

ON

OFF

OFF

OFF

4X

ON

ON

OFF

OFF

8X

ON

OFF

ON

OFF

16X

ON

ON

ON

OFF

32X

ON

OFF

OFF

ON

64X

ON

ON

OFF

ON

128X

ON

OFF

ON

ON

256X

ON

ON

ON

ON

Table 6.5

*The power must be turned OFF when switching in and out of Full Step mode.

7. COMMAND TABLES

Axis Configuration Commands

Function

Query/New

Code Value

Minimum

Maximum

Default

Hold Timeout

Q/N

HT

Numeric 100

5000

500

Percent Fast Decay Q/N

PF

Numeric 0

3

2

Table 7.1

General Operation Commands

Function

Query/New

Code Value

Minimum

Maximum

Default

Firmware Rev.

Q

FR

Numeric -

-

-

Table 7.2

R325P User Manual