RMS Technologies R325P DRIVER User Manual

Page 16

Advertising
background image

NOTE:

These recommendations will provide optimal protection against EMI and RFI. The actual

cable type, wire gauge, shield type and filtering devices used are dependent on the customer’s

application and system.

Driver Supply Cable AWG Table

1 Amp (Peak)

Length (Feet)

10

25

50*

75*

100*

Minimum AWG

20

20

18

18

16

2 Amps (Peak)

Length (Feet)

10

25

50*

75*

100*

Minimum AWG

20

18

16

14

14

3 Amps (Peak)

Length (Feet)

10

25

50*

75*

100*

Minimum AWG

18

16

14

12

12

* Use the alternative methods illustrated in Examples B and C

when the cable length is ≥ 50 feet. Also, use the same current

rating when the alternate AC power is used

Driver Supply Cable Wire Size

NOTE: Always use Shielded/Twisted Pairs for the Driver DC Supply Cable, the AC Supply Cable

and the Driver to Motor Cable.

R325P User Manual

Page 16 of 20

5/29/2013 Version 1.01

Advertising