1 acquiring / changing the edid, 2 resetting the default edid – Kramer Electronics VS-41HDCP User Manual

Page 13

Advertising
background image

10

VS-41HDCP - Operating the VS-41HDCP

6.2.1

Acquiring / Changing the EDID

You can work with the default EDID or acquire or change an EDID via the

connected output. Use the EDID button to acquire the output EDID information.

To acquire or change the EDID of a new output display:

1. Connect the power supply.

2. Connect the new output display device.

The EDID button blinks.

3. Press the EDID button.

The INPUT buttons blink in sequence until the EDID is acquired.

6.2.2

Resetting the Default EDID

To reset the default EDID, disconnect the output and repeat the steps in

Section

‎6.2.1

.

6.3

Controlling via the REMOTE Terminal Block Connector

The contact closure remote control pins operate in a similar way to the INPUT

SELECTOR button. Using the contact closure remote control you can select the

DVI input. To do so, momentarily connect the required input pin (IN 1, IN2, IN 3 or

IN 4) on the REMOTE terminal block connector to the GND (Ground) pin, as

Figure 4

illustrates.

DO NOT connect more than one PIN to the GND PIN at the same

time.

Figure 4: Connecting the Contact Closure Remote Control PINs

!

Advertising