Communication Protocol

The FC-41 is compatible with the protocol (ver 1.2) described below. For RS-232,

a null-modem connection between the FC-41 and controller is used. The default

data rate is 9600 baud, with no parity, 8 data bits and 1 stop bit. All the values

shown are hexadecimal.

Instruction

Byte 1

Byte 2

Byte 3

Byte 4

Notes:

RESET

00

80

80

98+Machine
Addr

REPLY TO
RESET

40

80

80

98+Machine
Addr

READ LOCAL
PARAMETER

20

80+Parameter
Number

80

B8+Machine
Addr

REPLY TO READ
LOCAL
PARAMETER

60

80+Parameter
Number

80+Parameter
Data

B8+Machine
Addr

WRITE LOCAL
PARAMETER

21

80+Parameter
Number

80+Parameter
Data

B8+Machine
Addr

REPLY TO
WRITE LOCAL
PARAMETER

61

80+Parameter
Number

80+Parameter
Data

B8+Machine
Addr

1

READ GLOBAL
PARAMETER

20

80+Parameter
Number

80

98+Machine
Addr

REPLY TO READ
GLOBAL
PARAMETER

60

80+Parameter
Number

80+Parameter
Data

98+Machine
Addr

WRITE GLOBAL
PARAMETER

21

80+Parameter
Number

80+Parameter
Data

98+Machine
Addr

REPLY TO
WRITE GLOBAL
PARAMETER

61

80+Parameter
Number

80+Parameter
Data

98+Machine
Addr

1

SAVE

23

80 + Initial
Setup
Number

80+Destination
Setup Number

98+Machine
Addr

2

IDENTIFY
MACHINE

3D

81

80

98+Machine
Addr

3

IDENTIFY
FIRMWARE
VERS.

3D

83

80

98+Machine
Addr

4