Kramer Electronics FC-41 User Manual

Page 18

Advertising
background image

FC-41 - Communication Protocol

15

The following table defines the local parameter data:

Local Parameter Number

Local Parameter Data

Description

#

Input Standard

01

0 - 720p/60

1 - 720p/59

2 - 720p/50

3 - 1080i/60

4 - 1080i/59

5 - 1080i/50

6 - 1080p/30

7 - 1080p/29

8 - 1080p/25

9 - 1080p/24

A - 1080p/23

B - 1080sf/30

C - 1080sf/29

D - 1080sf/25

E - 1080sf/24

F - 1080sf/23

Mode Input Standard

02

0 - Auto

1 - Forced

SYNC Type

04

0 - Bi-Level

1 - Tri-Level

Test Signal

05

0 - NO TEST SIGNAL

1 - COLOR BAR 100%

2 - Y-SWEEP 30 MHZ

3 - PULSE 2T AND BAR

4 - Y-RAMP

5 - C-SWEEP 15 MHZ

6 - RAINBOW

7 - GRID

8 - GRID INVERSE

Black

08

-32% - +31% (1% step)

Y-gain

09

-64% - +63% (1% step)

Gain

0A

-64% - +63% (1% step)

Color

0B

-64% - +63% (1% step)

B-Y

0C

-64% - +63% (1% step)

R-Y

0D

-64% - +63% (1% step)

Sharpness

0E

0% - +150% (10% step)





Advertising