Kramer Electronics FC-41 User Manual

Page 19

Advertising
background image

16

FC-41 - Communication Protocol

The following table defines the global parameter data:

Global Parameter Number

Global Parameter Data

Description

#

Panel Lock

00

0 - Off (Default)

1 - On

Machine Address

01

0,1

Setup Number

02

0 - 15

Free Run Mode

03

0 - Black Screen (Default)

1 - Blue Screen

Input Standard
(Read Only)
(AUTO Mode Only)

08

0 - 720p/60

1 - 720p/59

2 - 720p/50

3 - 1080i/60

4 - 1080i/59

5 - 1080i/50

6 - 1080p/30

7 - 1080p/29

8 - 1080p/25

9 - 1080p/24

A - 1080p/23

B - 1080sf/30

C - 1080sf/29

D - 1080sf/25

E - 1080sf/24

F -1080sf/23

10 - Not Identified

11 - Not Identified

Presence of Input Signal
(Read Only)

09

0 - Input Signal is Present

1 - No Input Signal


NOTE 1: These commands are sent by the unit also when Local / Global parameters are changed via the front panel or
as a result of execution of any other command.

NOTE 2: If it is necessary merely to save adjusted parameters in initial setup number (no setup number change), then
the value of byte3 must be equal to the value of byte2 - initial setup number.

NOTE 3: The reply to the Identify Machine command shows the machine name
- 1st byte: 0x7d
- 2nd byte: 0x80 + 0x00 (0 dec)
- 3rd byte: 0x80 + 0x29 (41 dec) - for the unit FC-41
- 4th byte: 0x98

NOTE 4: The reply to the Identify Firmware command shows the firmware version as
- 1st byte: 0x7d
- 2nd byte: 0x80 + the version number prior to decimal point
- 3rd byte: 0x80 + the version number following the decimal point
- 4th byte: 0x98
For example, for version 3.5, the reply would be 0x7d, 0x83, 0x85, 0x98.

Advertising