Table 10 tapered increaser height – M&G DuraVent DuraStack® User Manual

Page 14

Advertising
background image

14

Figure 15

45° tEE y (ty)

1. This kind of tee is useful where the stack
is located between two application or with
a double exhaust system. Use the same
support method and thermal expansion
considerations from the other tees (See

Figure 14).

tEE Cap (tC)

1. Use to block one of the openings of
horizontal or vertical tee.

2. Removable, it facilitates access for
inspection and maintenance of the chimney.

3. The installation is the same as for lengths.

Figure 16

Table 10

Tapered Increaser Height

Step

1" Diameter

2" Diameters

3" Diameters

C

4"

8"

12"

4. When removed, the old silicone must be
cleaned out and a new bed of sealant must
be applied.

DraIn-tEE Cap (DtC)

1. Use as a drain for vertical stack.

2. Connect to a suitable drain fitting to allow
rain entering the chimney to wash down,
dilute and remove any corrosive residue.

3. Same installation as a tee cap.

InCrEaSEr, StEp or tapErED

1. Use to increase the diameter of the
chimney flue.

2. The tapered increaser induce less pressure
drop than the step increaser, but requires
more space. It has a 15° side angle and

Figure 14

Figure 13

* See Table 10

45°

Tee

Expansion

Length

Increaser

Appliance

Stationary

Fix

Support

Expansion

Length

Increaser

45° Elbow

45° Tee Y

Tee

Cap

Drain-Tee

Cap

Ø B

Ø B

Ø A

Ø A

C

2"

2"

6"

Appliance

Appliance

Appliance

Advertising