9table 5 sealant usage – M&G DuraVent DuraStack® User Manual

Page 9

Advertising
background image

9

Table 5

Sealant Usage

Interior Installation

Sealant

Application

Supplier

Model

Color

Max.

Temp.

Joints

DuraVent

S-650

Red

650°F

Inner Flue

DuraVent

S-2000

White

2000°F

Exterior Installation

Sealant

Application

Supplier

Model

Color

Max.

Temp.

Joints

DuraVent

S-650

Red

650°F

Outer Band

DuraVent

S-375

Gray

375°F

CautIon

DO NOT ALLOW SCREWS TO PENETRATE
THE INNER FLUE. THIS CAN CAUSE
CORROSION, GAS LEAKAGE OR EXPANSION
FAILURE. NEVER USE SCREWS THROUGH
THE OUTER CASING OF AN ADJUSTABLE
LENGTH OR EXPANSION JOINT. OBSERVE
ADEQUATE SAFETY MEASURES WHEN
USING A DEGREASER.

Table 6

Maximum Chimney Heights and Support Method for Model DIS and DAS

Inside Diameter

Anchor Plate

Anchor Plate Ventilated (APV)

Wall Support (WS)

Tee (T)

Building Metal

Frame

Building Metal

Frame

Building Wood

Frame

Building Metal

Frame

Building Wood

Frame

5

147

133

133

147

61

105

6

128

116

116

128

53

92

8

103

93

93

103

43

74

10

86

78

78

86

35

61

12

73

66

66

73

30

53

14

64

58

58

64

27

46

16

57

52

52

57

24

41

18

53

48

48

53

22

38

20

48

43

43

48

20

34

22

44

40

40

44

18

31

24

37

34

34

37

15

27

26

35

32

32

35

14

25

28

33

30

30

33

13

23

30

31

28

28

31

13

22

32

29

26

26

29

12

21

34

27

25

25

27

11

20

36

26

23

23

26

11

18

Advertising