Next Advance Inc., a defective unit will be either repaired or replaced.

This warranty does not cover damage by any cause including, but not limited to, any malfunction, defect or
failure caused by or resulting from unauthorized service or parts, improper maintenance, operation
contrary to furnished instructions, shipping or transit accidents, modifications or repair by the user, harsh
environments, misuse, neglect, abuse, accident, incorrect line voltage, fire, flood, other natural disasters, or
normal wear and tear. Changes or modifications not approved by Next Advance Inc. could void the
warranty.

The foregoing is in lieu of all other expressed warranties and Next Advance Inc. does not assume or
authorize any party to assume for it any other obligation or liability.

1.4 Packing List

The Starter Kit for the SP2200 Multi-Phaser™ Programmable Syringe Pump includes the following items:

One of the following external unregulated power supply adapters:

Input: One of: 120V AC 60 Hz, 220V AC 50 Hz, 240V AC 50 HZ,

or other custom specified power supply

Output: 12V DC @ 1000 mA

Primary Computer RS-232 interface cable: CBL-PC-PUMP-7

This Operating Manual

2. Overview

The SP2200 is a general purpose single syringe pump capable of infusion and withdrawal. It is controlled
from a microcontroller based system which drives a step motor, allowing a large range of pumping rates
calibrated to the inside diameter of the loaded syringe. The syringe is driven from a drive-screw and drive-
nut mechanism.

Features:

 Infusion and withdrawal pumping of one or two

syringes up to 60 cc. 140 mL partially filled.

 Pumping rates from 1.459 L/hr with a 1 cc

syringe to 6120 ml/hr with a 60 cc syringe.

 Stall detection: Automatically stops pump when

pumping is impeded

 Infusion and withdrawal volumes separately

accumulated.

 Programmable dispense volumes.

 Programmable Phases allowing complex

pumping applications and interaction with
external devices.

 Program Sub-Programs, selectable by the user.

 Non-volatile memory of all operating

parameters and Pumping Program

 RS-232 bi-directional control from a computer.

 Built-in pump network driver. Pump network

supports up to 100 pumps and other devices.

 Two modes of RS-232 control, Basic and Safe.

Safe mode provides communication error
detection, loss of communication detection, and
automatic transmitting of alarm conditions.

 TTL logic I/O with firmware filtered control

inputs to eliminated glitches and ringing on the
control inputs.

 Configurable and programmable TTL

operational trigger for flexible logic control.

 Power Failure Mode: Restarts the Pumping

Program after a power interruption.

 Audible Alarm

 Many more features!

Advertising